Every experiment here does the same trick: let spins dephase, reverse the dephasing with a pulse, and read what the echo lost along the way. What it lost tells you about relaxation, diffusion, distances or local fields. This guide covers the equations and gives you sliders to test your intuition.
A nucleus with spin \(I\) and gyromagnetic ratio \(\gamma\) precesses at the Larmor frequency in a static field \(B_0\). Bulk magnetization \(\mathbf M\) follows the Bloch equations: it rotates about the effective field and relaxes longitudinally with \(T_1\) and transversely with \(T_2\). A real sample also sees a spread of static fields \(\Delta B_0\) (shim errors, susceptibility jumps, internal gradients). That spread dephases the signal faster, with \(T_2^{*}\). The spread is static, so a 180° pulse can undo it. That is the spin echo.
Order of timescales in liquids: \(T_2^{*}\le T_2\le T_1\) (with \(T_2 \approx T_1\) in the extreme-narrowing limit, \(\omega_0\tau_c\ll1\)).
| Nucleus | I | γ / 10⁶ rad s⁻¹T⁻¹ | ν₀ / MHz | Nat. ab. % | Receptivity vs ¹H | Polarization |
|---|
Receptivity \(\propto|\gamma|^3 I(I+1)\,C_\text{nat}\). Thermal polarization is parts per million at room temperature, which is why hyperpolarized probes (¹²⁹Xe, ³He, DNP) are 10⁴–10⁵ times brighter.
After a 90° pulse, each isochromat \(i\) accumulates phase \(\phi_i=\Delta\omega_i t\). A 180° pulse at \(\tau\) negates every phase, so the same offset that caused the dephasing now drives the rephasing. At \(2\tau\) all phases return to zero. What remains is attenuated only by processes that are not static on the scale of \(\tau\): true \(T_2\), diffusion through gradients, and exchange.
Each arrow is an isochromat, coloured by its frequency offset. The thick arrow is their vector sum, the measured signal. Raise the inhomogeneity: the FID collapses faster, but the echo peaks stay on the \(T_2\) envelope.
Spins that diffuse through a background gradient \(G\) between dephasing and refocusing do not come back fully. For a single echo the loss grows as \(\tau^3\). A CPMG train with short spacing \(t_E\) resets that loss every echo, so it only grows linearly with total time. This is the basis of low-field and well-logging relaxometry.
In the Stejskal–Tanner experiment two gradient pulses of area \(g\delta\) are placed around the 180° pulse, separated by \(\Delta\). Stationary spins are refocused exactly. Spins that moved acquire a random phase, and the echo is attenuated by \(e^{-bD}\). Molecular size follows from the Stokes–Einstein relation, which makes the diffusion coefficient itself a marker for aggregation, binding and viscosity.
Rule of thumb: pick δ and Δ so the last gradient step leaves 5–10 % of the signal. For mixtures (DOSY) that is the only way to separate components by \(D\). Sine-shaped gradients replace \(\delta^2\) by \((2\delta/\pi)^2\).
A spin probe is a spin you introduce on purpose because its interaction with its surroundings is easy to read out: a nitroxide or Gd³⁺ label that relaxes nearby nuclei (PRE), a lanthanide tag that shifts them (PCS), a pair of electron spins whose dipolar coupling gives a distance (DEER), a ¹⁹F or ¹²⁹Xe reporter with a large, background-free shift range, or a contrast agent in MRI. A marker or reference defines the frequency axis, so shifts are comparable between labs and fields.
\(K=\tfrac{1}{15}(\mu_0/4\pi)^2\gamma_I^2g_e^2\mu_B^2S(S+1)=1.23\times10^{-32}\ \text{cm}^6\,\text{s}^{-2}\) for a nitroxide and ¹H. Because \(\Gamma_2\propto r^{-6}\), a transient 1 % population at close range can dominate the PRE. That is why PRE sees lowly populated encounter complexes that averaged structures miss.
An anisotropic paramagnetic centre (Tb³⁺, Tm³⁺, Dy³⁺) shifts nuclear resonances by an amount that depends on distance and orientation relative to its \(\Delta\chi\) tensor. PCS reach 40–60 Å, much further than PRE, and carry angular information. The diamagnetic reference is La³⁺, Lu³⁺ or Y³⁺ in the same tag.
Rigid tags (two-armed, or bound to a single-site mutant) matter: tag mobility averages \(\Delta\chi\) and shrinks the shifts.
Gd³⁺ chelates are spin probes read out through water. Their efficiency is the relaxivity \(r_1\) (per mM per second). In Solomon–Bloembergen–Morgan theory it depends on hydration number \(q\), water residence time \(\tau_m\) and rotational correlation \(\tau_R\).
IUPAC recommends a single primary reference: the ¹H signal of TMS (organic solvents) or DSS (aqueous samples). Every other nucleus is referenced indirectly by the frequency ratio \(\Xi\). No second standard needs to go in the tube.
| Nucleus | Reference | Ξ / % | ν_ref / MHz |
|---|
Ξ values from Harris et al., Pure Appl. Chem. 73 (2001) 1795 and 80 (2008) 59; ¹³C and ¹⁵N (DSS / liquid NH₃) are the biomolecular convention of Wishart et al. (1995). Check your spectrometer's own table before publishing.
| Probe | Reads out | Why use it |
|---|---|---|
| ¹⁹F tags (CF₃, TFA, BTFA) | shift, T₂, PRE | No background in biology; 83 % of ¹H sensitivity; very environment-sensitive shift |
| Hyperpolarized ¹²⁹Xe | shift, exchange | Polarizable electron cloud gives a very wide shift range; senses cavities, cryptophane biosensors |
| ²H labels | quadrupolar echo | Order parameters and dynamics in membranes and solids |
| ¹³C/¹⁵N-labelled methyls | relaxation, CPMG-RD | Methyl-TROSY in large complexes; µs–ms exchange |
| Nitroxides (MTSL) | PRE, DEER | Cysteine-specific, small, S = ½ |
| Gd³⁺ / Ln³⁺ tags | PRE, PCS, RDC, DEER | Large moments; in-cell stability (Gd); orientation (PCS) |
| TEMPO, O₂, Gd-DTPA-BMA (solvent PRE) | solvent accessibility | Non-specific co-solutes that map exposed surfaces |
The same CPMG block from Lab 2 is used to measure µs–ms exchange. With exchange, \(R_{2,\text{eff}}\) depends on the pulsing rate \(\nu_\text{CPMG}=1/(2\tau_\text{cp})\). Fast pulsing refocuses the exchange contribution \(R_\text{ex}\).
A 180° pulse does not refocus homonuclear J couplings. Hahn and CPMG echoes of coupled spins are modulated by \(\cos(2\pi J\tau)\). Use short \(\tau\), perfect-echo variants, or fit the modulation.
With CP phase (all 180°ₓ), flip-angle errors accumulate. The Meiboom–Gill 90° phase shift, or XY-4/XY-16 cycling, keeps the train stable, but it can also spin-lock and bias \(T_2\) toward \(T_{1\rho}\).
Temperature gradients fake fast diffusion. Use convection-compensated double-stimulated echoes, narrow tubes, and bipolar gradients with an LED delay.
Reduce the nitroxide (ascorbate) or use a diamagnetic metal in the same tag. Check for label-induced structural changes and intermolecular PRE by mixing labelled ¹⁴N and unlabelled ¹⁵N protein.
Wait at least 5 \(T_1\) (99.3 % recovery) for quantitative work. Probe-doped samples shorten \(T_1\), which is one reason to add a relaxation agent.
A trace of length \(t_\text{max}\) reliably gives mean distances only up to about \(5\,\text{nm}\,(t_\text{max}/2\,\mu\text{s})^{1/3}\), and widths up to about 4 nm at 2 µs. Deuterate the solvent to extend the phase-memory time.
Filter by topic. The copy button puts the LaTeX source on your clipboard, ready for a thesis chapter.